Schneider Electric ATS22D47Q Soft starter, Altistart 22, ATS22 control 220V power 230V(11kW)/400...440V(22kW)
Code: SCHATS22D47Q
Unit of measure:
EACH
Description
Soft Start/Stop Unit
Brand Name: Schneider
Range: Altistart 22
Voltage: 230 - 440 V
Current: 47 A
Power Rating: 11 - 22 kW
Phase: 3
Frequency Rating: 50 - 60 Hz
Degree of Protection: IP20
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Product destination | asynchronous motors |
Relative humidity | 0-95 % without condensation or dripping water conforming to IEC 60068-2-3 |
[Us] rated supply voltage | 230...440 V - 15...10 % |
Discrete input voltage | 24 V <= 30 V |
Operating position | vertical +/- 10 degree |
Electromagnetic compatibility | electrostatic discharge level 3 conforming to IEC 61000-4-2 |
Ambient air temperature for operation | 40-60 °C (with current derating 2.2 % per °C) |
Connector type | 1 RJ45 |
Minimum switching current | 100 mA at 12 V DC (relay outputs) |
Noise level | 45 dB |
Installed device | 31 |
Motor starter type | soft starter |
Supplier Code | ATS22D47Q |
Component name | ATS22 |
Supply voltage limits | 195-484 V |
Ambient air temperature for storage | -25-70 °C |
Discrete output type | relay outputs R2 230 V running- alarm- trip- stopped- not stopped- starting- ready C/O |
Network frequency | 45...66 Hz |
Power dissipation in W | 48 W for standard applications |
PTC probe input | 750 Ohm |
Vibration resistance | 1.5mm (f= 2-13 Hz) conforming to IEC 60068-2-6 |
Communication data link | serial |
Discrete input number | 3 |
Network number of phases | 3 phases |
Function available | internal bypass |
Protection type | thermal protection: starter |
Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Motor power kW | 22 kW 400 V |
Device connection | in the motor supply line |
Communication port protocol | Modbus |
IP degree of protection | IP20 |
Range | Altistart 22 |
Item Name | Soft Starter |
Assembly style | with heat sink |
Pollution degree | level 2 conforming to IEC 60664-1 |
Current | 47A |
Output current | 0.4...1 Icl adjustable |
Phase | 3 Phase |
Power range | 15-25 kW at 380-440 V 3 phases |
Product specific application | pumps and fans |
Control circuit consumption | 20 W |
Standard | CE, CCC, CSA, UL Listed |
Factory setting current | 42 A |
IcL starter rating | 47 A for connection in the motor supply line for standard applications |
Discrete input logic | positive logic LI1- LI2- LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V- >= 5 mA |
Depth | 169mm |
Type of start | start with torque control (current limited to 3.5 In) |
Voltage | 230 - 440V |
Maximum switching current | 2 A 250 V AC inductive 0.4 20 ms relay outputs |
Height | 265mm |
Width | 130mm |
Operating altitude | > 1000...< 2000 m with current derating of 2.2 % per additional 100 m |
Type of cooling | forced convection |
[Uc] control circuit voltage | 230 V - 15...10 % 50/60 Hz |
Discrete output number | 2 |
Marking | CE |
Standards | IEC 60947-4-2 |
Product certifications | C-Tick |
Brand Name | Schneider Electric |
Supply frequency | 50...60 Hz - 10...10 % |
Utilisation category | AC-53A |
Discrete input type | (LI1- LI2- LI3) logic- 5 mA 4.3 kOhm |
Net weight | 7 kg |
Transmission rate | 4800- 9600 or 19200 bps |
Physical interface | RS485 multidrop |
Product or component type | soft starter |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now