Schneider Electric LR2K0308 Differential thermal overload relay, TeSys LR2 K, TeSys K, 1.8...2.6A, class 10A
Code: SCHLR2K0308
Unit of measure:
EACH
Description
Schneider LR2K0308 Overload Relay, 690VAC/250VDC, 1.8-2.6A, 1NO+1NC, Automatic/Manual Reset, For LC1K, LP1K, LC7K, LP4K Contactors
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Thermal overload class | class 10A conforming to IEC 60947-4-1 |
Ambient air temperature for operation | -30-60 °C with derating conforming to IEC 60947 |
Current Type | AC/DC |
Supplier ref | LR2K0308 |
Contactor | LC1K, LP1K, LC7K, LP4K |
[Ith] conventional free air thermal current | 6 A for signalling circuit |
Supplier Code | LR2K0308 |
Ambient air temperature for storage | -40-70 °C |
Trip Class | Class 10A |
Network frequency | <= 400 Hz |
Network type | AC |
Terminal Type | Screw Clamp |
Control type | blue push-button: stop and manual reset |
IP degree of protection | IP2X conforming to IEC 60529 |
Range | TeSys |
Flame retardance | requirement 2 conforming to NF F 16-101 |
Item Name | Overload Relay |
Protective treatment | TC conforming to DIN 50016 |
Local signalling | trip indicator (yellow) |
Tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Thermal protection adjustment range | 1.8-2.6 A |
Auxiliary contact composition | 1 NO + 1 NC |
Current | 1.8 - 2.6A |
Connections - terminals | screw clamp terminals 2 cable(s) 1.5-4mm²solid |
Associated fuse rating | 6 A gG for signalling circuit conforming to IEC 60947 |
Standard | CSA, UL Listed |
Depth | 65mm |
Mounting support | plate- with specific accessories |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Voltage | 690 VAC/250 VDC |
Degree of Protection | IP2X |
Height | 58mm |
Width | 45mm |
Operating altitude | 2000 m without derating |
Device short name | LR2K |
Phase failure sensitivity | yes conforming to IEC 60947-4-1 |
Compatibility code | LR2K |
Product compatibility | LP1K |
Mechanical robustness | vibrations NO contact: 2 Gn- 5...300 Hz conforming to IEC 60068-2-6 |
[Ue] rated operational voltage | 250 V DC DC-13 for signalling circuit |
[Ui] rated insulation voltage | power circuit: 750 V conforming to VDE 0110 group C |
Standards | NF C 63-650 |
Product certifications | CSA |
Brand Name | Schneider Electric |
EAN/UPC | 3389110230444 |
[Uimp] rated impulse withstand voltage | 6 kV |
Power dissipation per pole | 2 W |
Contact Configuration | 1 NO + 1 NC |
Reset Type | Automatic/Manual |
Product name | TeSys LRK |
Relay application | motor protection |
Net weight | 0.145 kg |
Product or component type | differential thermal overload relay |
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?