Description
Fluke TiS75PRO9Hz/42 TIS75 Pro Thermal Imager, JQ2, 9HZ, 42X32, APAC
384 x 288 high-definition infrared resolution. The robust quality lens with SuperResolution mode enables user to achieve high image quality. Various applications can be supported such as equipment maintenance, R&D and quality control.
Features:
• 384 x 288 infrared resolution
• 3.5-inch touchscreen
• Measure up to 650 °C, suitable for many application scenarios, such as equipment maintenance, R&D and quality control
• Manual focus and Focus free
• Built-in route inspection function to simplify and standardize inspection
• Preset shortcut button key for quick access to function.
• Share image wireless via transfer to mobile phones or PCs
• Delta T calculation of 3 phase systems
• QR code scanning for asset tagging
• Supported with Fluke Connect Express reporting software
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Relative humidity | 10% to 95% non-condensing |
| Ergonomic design | Designed specifically for one-handed use |
| Memory review | Yes |
| Safety standards | IEC 61010-1: pollution degree 2 |
| Digital Zoom | 1-4x |
| Australia RCM | RCM IEC 61326-1 |
| Auto high/low temperature capture | High and low temperature points marked and tracked automatically |
| Flashlight | Yes |
| Ingress protection | IEC 60529: IP52 |
| Batteries (field-replaceable, rechargeable) | Lithium-ion rechargeable battery |
| Battery charging time | < 4 hours to full charge |
| Preset measurement parameters (profile) | Up to 50 profiles can be saved |
| Recommended calibration period | 2 years |
| Severity annotations | Yes, annotations for the 4 severity levels: normal, moderate, severe, and extreme |
| Supplier Code | TiS75 PRO 9Hz/42 |
| Agile Focus | Yes |
| Minimum span (in auto mode) | 3 °C |
| Temperature span | -20 °C to 650 °C |
| Warranty | 2 years |
| Weight (battery included) | 950 g |
| Field of view | 42°: 42° x 32° |
| Dew point calculation | Yes |
| Type-C interface | Charging, data transfer, remote display and control supported [3] |
| Drop | Engineered to withstand 2 m drop |
| Automatic reporting and trend summaries | Yes |
| Preset shortcut keys | 6 |
| Supported Languages | Simplified Chinese, Traditional Chinese, English, Korean, Japanese |
| Thermal images classified and archived automatically according to inspection routes | Yes |
| Voice annotation | Yes, 60 s maximum audio recording via a Bluetooth Audio Headset |
| On-screen temperature correction | Yes, emissivity, background temperature, measurement distance and transmission correction supported |
| Image mode | Infrared, visible light, PIP, visible light and infrared fusion |
| Custom temperature difference calculation | 3 |
| Asset tagging | Yes, name thermal images automatically by scanning QR codes or barcodes and save them as asset tags for thermal images |
| IR-Fusion technology | Blend continuous 0% to 10 %. 1% step for adding visible details to infrared images |
| Spot temperature | Center spot (unmovable) |
| Create and manage inspection routes | Yes, use the Fluke Connect Express software |
| Fast auto-rescale in manual mode | Yes |
| Standard software: Fluke Connect Express | Yes, functions such as thermal image analysis, historical trend generation, custom reports, and inspection management supported |
| Start, execute and manage inspection routes | Yes, use the thermal imager |
| Storage temperature | -20 °C to 60 °C, without batteries |
| External power supply | AC operation through the included power adapter with the output: 15 VDC, 2 A |
| Built-in digital camera (visible light) | 13 mp |
| Thermal sensitivity | <= 40 mk (0.04 ℃) |
| Minimum span (in manual mode) | 3 °C |
| Image file formats | JPEG (with temperature data) |
| Picture-in-Picture (PIP) | Yes |
| Image capture, review, save mechanism | One-handed image capture, review, and save capability |
| SuperResolution | 768 x 576 |
| Radio output power (WIFI and Bluetooth) | <100 mW |
| Standard accessories | One thermal imager, Two batteries, One 2-Bay Battery Charging Base, One soft bag, One hard case, One SD card, One AC adapter |
| Infrared Spectral band | 8 to 14 µm |
| Minimum focus distance | 42°: 0.1 m |
| Focus system | Manual focus + focus free |
| 3-phase maximum temperature difference calculation | Yes |
| IR-PhotoNotes | Yes. Up to 3 extra visible light images captured can be included in JPEG files |
| IFOV | 42°: 1.91 mRad |
| Detector type | Uncooled focal plane infrared detector |
| Temperature level and span | Smooth auto and manual scaling |
| Frame rate | 30 Hz |
| Color alarm | Yes, above the temperature, below the temperature, within the temperature span, outside the temperature span |
| Radio frequency (WIFI and Bluetooth) | 2.4 GHz |
| RoHS3 Directive | Yes |
| Wireless connectivity | Yes, direct transfer thermal images wirelessly to mobile phones or PCs |
| Brand Name | Fluke |
| Size (L x H x W) | ∼ (26.7 cm x 10.1 cm x 14.5 cm) |
| Text annotations | Yes, multiple languages supported |
| Laser | IEC 60825-1, Class 2 |
| IR resolution | 384 x 288 (110,592 pixels) |
| Auto capture (temperature and interval) | Yes, user-selectable time interval for capturing images. |
| Fully-radiometric infrared data streaming | Connection with a PC to transfer fully-radiometric infrared data streaming in real time |
| Operating temperature | -10 °C to 50 °C |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
We can source just about anything, submit a request and we'll get back to you soon.