Description
Schneider Electric A9C20132 iCT 25A 2NO 24V 50Hz contactor, White
This Acti9 iCT is a modular contactor. It is a 2P remote control device with 2 normally open contacts. The rated current is 25A for AC-7a and 8.5A for AC-7b. The Ue rated operational voltage is 250VAC. The Uc control voltage is 24VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 2 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 81mm x (H) 18mm x (D) 68.5mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.
Features:
• Could be used for control circuits and remote switching small motors such as fans, mixers
• Compliant to IEC 61095 standard
• Mechanical contact position indicator
• Clip-on system for electrical and mechanical connections between contactors up to 25A and their auxiliaries
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Relative humidity | 95-95 % at 55-55 °C |
| Ambient air temperature for operation | -5-60 °C |
| Noise level | 30 dB |
| Mounting mode | clip-on |
| Switching frequency | 100 switching operations/day |
| Supplier Code | A9C20132 |
| Ambient air temperature for storage | -40-70 °C |
| Network frequency | 50 Hz |
| 9 mm pitches | 2 |
| Inrush power in VA | 15 VA |
| Network type | AC |
| Hold-in power consumption in VA | 3.8-3.8 VA |
| Control type | remote control |
| IP degree of protection | IP40 (modular enclosure) conforming to IEC 60529 |
| Range | Acti9 |
| Electrical durability | 30000 cycles IEC/EN 61095 50 Hz AC-7C |
| Local signalling | action indicator |
| Pollution degree | 2 |
| Tightening torque | power circuit: 0.8-0.8 N.m |
| Market segment | small commercial |
| [Ie] rated operational current | 8.5 A AC-7B |
| Connections - terminals | control circuit: tunnel type terminals2 cable(s) 1.5-2.5mm² flexible |
| Control signal type | maintained |
| Depth | 68.5mm |
| Colour | White |
| Mounting support | 35mm symmetrical DIN rail |
| Pole contact composition | 2 NO |
| Power losses per pole | 1.4 W |
| Mechanical durability | 1000000 cycles |
| Height | 81mm |
| Poles description | 2P |
| Width | 18mm |
| Operating altitude | 2000 m |
| [Uc] control circuit voltage | 24 V AC 50 Hz |
| Tropicalisation | 2 conforming to IEC 1095 |
| Device short name | iCT |
| Compatibility code | iCT |
| Product compatibility | iACTc |
| Device application | motor-heating-lighting |
| [Ue] rated operational voltage | 250 V AC 50 Hz |
| Total power losses | 2.8 W |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
| Standards | IEC/EN 61095 |
| Brand Name | Schneider Electric |
| Heat dissipation | 1.3-1.3 W at 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Product name | Acti9 iCT |
| Maximum power | 1.3 W at 250 V AC |
| Product or component type | contactor |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
We can source just about anything, submit a request and we'll get back to you soon.