Schneider Electric A9D51825, Residual current breaker with overcurrent protection (RCBO), Acti9 iC60H RCBO, 1P+Ns, 25A, D curve, 30mA, A type, 10000A
Code: SCHA9D51825
Unit of measure:
EACH
Description
Schneider Electric A9D51825, Residual current breaker with overcurrent protection (RCBO), Acti9 iC60H RCBO, 1P+Ns, 25A, D curve, 30mA, A type, 10000A
Residual current breaker with overcurrent protection (RCBO), Acti9 iC60H RCBO, 1P+Ns, 25A, D curve, 30mA, A type, 10000A
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Relative humidity | 95-95 % at 55-55 °C |
| Number of protected poles | 1 |
| Surge current | 250 A |
| Residual current tripping technology | voltage dependent |
| Ambient air temperature for operation | -15-60 °C |
| [Ics] rated service breaking capacity | 7500 A at 230/240 V AC 50/60 Hz |
| Earth-leakage protection | integrated |
| Mounting mode | clip-on |
| Breaking capacity code | H |
| Comb busbar and distribution block compatibility | YES |
| Earth-leakage sensitivity | 30 mA |
| Ambient air temperature for storage | -40-85 °C |
| Network frequency | 50/60 Hz |
| Neutral position | left |
| [Icw] rated short-time withstand current | Icw: 250 A during 8/20 µs impulse withstand |
| 9 mm pitches | 2 |
| Circuit breaker application | distribution |
| Earthing system | TN |
| Network type | AC |
| IP degree of protection | IP20 |
| Range | Acti9 |
| Curve code | D |
| Electrical durability | 5000 cycles |
| Local signalling | ON/OFF indication |
| Tightening torque | power circuit: 2-2 N.m bottom |
| Earth-leakage protection class | type A |
| Connections - terminals | screw clamp terminal (top) 1-16 mm² flexible |
| Provision for padlocking | padlockable with padlock Ø 4 mm |
| Contact position indicator | yes |
| Suitability for isolation | yes |
| [In] rated current | 25 A at 50 °C |
| Earth-leakage protection time delay | instantaneous |
| Depth | 77.5 mm |
| Colour | white |
| Mounting support | DIN rail |
| control type | toggle |
| Mechanical durability | 20000 cycles |
| Breaking capacity | 10000 A Icn at 230/240 V AC 50/60 Hz |
| Height | 110 mm |
| Limitation class | 3 |
| Poles description | 1P + Ns |
| Width | 18 mm |
| Wire stripping length | power circuit: 14 mm for top connection |
| Device short name | iC60H |
| Tropicalisation | 2 |
| Trip unit technology | thermal-magnetic |
| [Ue] rated operational voltage | 230/240 V AC 50/60 Hz |
| Device location in system | outgoer |
| [Ui] rated insulation voltage | 400 V AC 50/60 Hz |
| Standards | AS/NZS 61009.1 |
| Brand Name | Schneider Electric |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Locking options description | ON/OFF locking facilities |
| Net weight | 205 g |
| Product or component type | residual current breaker with overcurrent protection (RCBO) |