Description
Schneider Electric C1635E160 Trip unit MicroLogic 5.2E, ComPacT NSX160/250, 3 poles, electronic basic protections, energy meter, 160A rating
This MicroLogic 5.2 E (Energy) is a 3 poles 3d electronic trip unit used on ComPacT NSX 160/250 circuit breakers. This 160A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. MicroLogic 5.2 E indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. MicroLogic 5.2 E is equipped with a display module that gives energy measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and ComPacT NSX basic frame.
Features:
• Estimated 40% reduction of wiring time for panel builders
• Experience easier installation thanks to a new ergonomic front-plate design
• Gain the confidence that all auxiliaries are on the right spot, and check that you have the right coil rating
• Ergonomic new toggle for easier breaker manual operation
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Long time pick-up adjustment type Ir | adjustable 9 settings |
| [In] rated current | 160 A at 40 °C |
| Ambient air temperature for operation | -25-70 °C |
| Instantaneous pick-up adjustment type Ii | adjustable |
| Earth-leakage protection | without |
| Mounting mode | fixed |
| Type of measurement | energy meter |
| Supplier Code | C1635E160 |
| Instantaneous pick-up adjustment range | 1.5...15 x In |
| Zone selective interlocking ZSI | with |
| Ambient air temperature for storage | -40-85 °C |
| Poles description | 3P |
| Trip unit name | MicroLogic 5.2 E |
| Network frequency | 50/60 Hz |
| [Isd] short-time pick-up adjustment range | 1.5...10 x Ir |
| Short-time delay adjustment type | adjustable |
| Trip unit protection functions | LSI |
| Thermal memory | 20 minutes before and after tripping |
| Display type | LCD display |
| Protected poles description | 3D |
| [tsd] short-time delay adjustment range | 0.1-0.4 s I²t=on |
| Protection type | S : for short time short-circuit protection |
| Network type | AC |
| Trip unit technology | electronic |
| Device application | distribution |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Range | ComPacT new generation |
| Standards | EN/IEC 60947-2 |
| Long time pick-up adjustment range | 63...160 A |
| Brand Name | Schneider Electric |
| Electrical shock protection class | class II |
| 1 | https://visuals.se.com/C2535E250-360VH/20230420T0621/360 |
| [tr] long-time delay adjustment range | 0.5-16 s at 6 x Ir |
| Communication of data | time-stamped histories and event tables |
| Range compatibility | ComPacT new generation NSX250 |
| Local signalling | LED 105 % Ir (red) for overload |
| Pollution degree | 3 conforming to IEC 60947-1 |
| Long time delay adjustment type | adjustable |
| Short-time pick-up adjustment type Isd | adjustable 9 settings |
| Product or component type | trip unit |
| Electrical data recording | maintenance indicators |