Schneider C16N3TM125 Circuit Breaker MCCB ComPacT NSX160N3 Pole 125 Amp, 415Volt 50kA TM-D trip
Code: SCHC16N3TM125
Unit of measure:
EACH
Description
Schneider C16N3TM125 Circuit Breaker MCCB ComPacT NSX160N3 Pole 125 Amp, 415Volt 50kA TM-D trip
• Protection against overloads, short-circuits with additional motor-specific protection (phase unbalance, locked rotor, underload and long start) with MicroLogic 6 E-M trip units.
• The exceptional limiting capacity of ComPacT NSX circuit breakers automatically provides type-2 coordination with the motor starter, in compliance with standard IEC 60947-4-1
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Relative humidity | 0-95 % |
| Long time pick-up adjustment type Ir | adjustable |
| Downside connection | front |
| Ambient air temperature for operation | -25-70 °C |
| Instantaneous pick-up adjustment type Ii | fixed |
| [Ics] rated service breaking capacity | 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Earth-leakage protection | without |
| Mounting mode | fixed |
| Breaking capacity code | N 50 kA 415 V AC |
| Supplier Code | C16N3TM125 |
| Ambient air temperature for storage | -50-85 °C |
| Trip unit name | TM-D |
| Network frequency | 50/60 Hz |
| Trip unit protection functions | LI |
| Protection type | I : for short-circuit protection (magnetic) |
| Network type | AC |
| Control type | toggle |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Range | ComPacT NSX160N |
| Overvoltage category | class II |
| Long time pick-up adjustment range | 0.7...1 x In |
| Mounting | Fixed |
| Electrical shock protection class | class II |
| Electrical durability | 15000 cycles at 690 V In/2 |
| Mounting position | flat on the back |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Rated Current | 125 Amp |
| Trip unit rating | 125-125 A at 40 °C |
| Category | Circuit Breakers |
| Suitability for isolation | yes conforming to EN/IEC 60947-2 |
| [In] rated current | 125 A at 40 °C |
| Depth | 86mm |
| Connection pitch | 35mm |
| Mounting support | backplate |
| Instantaneous pick-up adjustment range | 1250 A |
| Mechanical durability | 40000 cycles |
| Voltage | 415VAC |
| Breaking capacity | 50kA |
| Height | 161mm |
| Poles description | 3P |
| Width | 105mm |
| Operating altitude | 2000 m...5000 m with derating |
| Protected poles description | 3D |
| Device short name | NSX160N |
| Compatibility code | NSX160 |
| Trip unit technology | thermal-magnetic |
| Device application | distribution |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Pole Configuration | 3 Pole |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| Standards | EN/IEC 60947-2 |
| Brand Name | Schneider Electric |
| [tr] long-time delay adjustment range | 15-15 s at 6 x Ir |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Upside connection | front |
| Power dissipation per pole | 10.78 W |
| Product name | ComPacT NSX new generation |
| Utilisation category | category A |
| Net weight | 2.2 kg |
| Long time delay adjustment type | fixed |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Number of slots | 5 slot(s) |
| Product or component type | circuit breaker |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.