Schneider Electric LC1D150U7 Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 150A, 240V AC 50/60Hz coil, screw clamp terminals
Code: SCHLC1D150U7
Unit of measure:
EACH
Description
CONTACTOR
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Contactor application | motor control |
| Maximum operating rate | 1200 cyc/h at 60 °C |
| Non-overlap time | 1.5 ms on energisation between NC and NO contact |
| Minimum switching current | 5 mA for signalling circuit |
| Irms rated making capacity | 1660 A at 440 V for power circuit conforming to IEC 60947 |
| Signalling circuit frequency | 25...400 Hz |
| [Ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
| Supplier Code | LC1D150U7 |
| [Icw] rated short-time withstand current | 140 A - 100 ms for signalling circuit |
| Inrush power in VA | 280-350 VA 50 Hz cos phi 0.9 (at 20 °C) |
| Hold-in power consumption in VA | 2-18 VA 50 Hz cos phi 0.9 (at 20 °C) |
| Motor power kW | 22 kW at 400 V AC 50/60 Hz (AC-4) |
| Safety reliability level | B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Range | TeSys |
| Flame retardance | V1 conforming to UL 94 |
| Overvoltage category | III |
| Electrical durability | 0.85 Mcycles 150 A AC-3e at Ue <= 440 V |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Protective cover | with |
| Pollution degree | 3 |
| Tightening torque | control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ie] rated operational current | 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| Connections - terminals | power circuit: connector 2 10-50mm² - cable stiffness: flexible with cable end |
| Control circuit type | AC at 50/60 Hz |
| Associated fuse rating | 315 A gG at <= 690 V coordination type 1 for power circuit |
| Depth | 136mm |
| Mounting support | rail |
| Pole contact composition | 3 NO |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical durability | 8 Mcycles |
| Permissible ambient air temperature around the device | 60-70 °C with derating |
| Climatic withstand | conforming to IACS E10 exposure to damp heat |
| Coil technology | built-in bidirectional peak limiting diode suppressor |
| Minimum switching voltage | 17 V for signalling circuit |
| Height | 158mm |
| Poles description | 3P |
| Width | 120mm |
| Operating altitude | 0...3000 m |
| Operating time | 40...75 ms opening |
| Device short name | LC1D |
| [Uc] control circuit voltage | 240 V AC 50/60 Hz |
| Compatibility code | LC1D |
| Auxiliary contacts type | type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Mechanical robustness | vibrations contactor closed (4 Gn- 5...300 Hz) |
| [Ue] rated operational voltage | power circuit: <= 300 V DC |
| [Ui] rated insulation voltage | signalling circuit: 690 V conforming to IEC 60947-1 |
| Contact compatibility | M13 |
| Standards | EN 60947-4-1 |
| Control circuit voltage limits | 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz |
| Brand Name | Schneider Electric |
| Product certifications | CSA |
| Heat dissipation | 3-4.5 W at 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
| Power dissipation per pole | 13.5 W AC-3e |
| Motor power hp | 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors |
| Rated breaking capacity | 1400 A at 440 V for power circuit conforming to IEC 60947 |
| Utilisation category | AC-1 |
| Net weight | 2.5 kg |
| Product or component type | contactor |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.