Schneider Electric LC1D65U7 Contactor, TeSys Deca,3P(3NO),AC-3/AC-3e/<=440V 65A,240V AC 50/60Hz coil, screw clamp terminals
Code: SCHLC1D65U7
Unit of measure:
EACH
Description
Schneider Electric LC1D65U7 Contactor, 1NO+1NC, 240V, 65A, 37kW, 3 Pole, 50Hz
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Contactor application | resistive load |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contacts |
| Minimum switching current | 5 mA for control circuit |
| Irms rated making capacity | 140 A AC for control circuit conforming to IEC 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for control circuit |
| Supplier Code | LC1D65U7 |
| [Icw] rated short-time withstand current | 900 A 40 °C - 1 s for power circuit |
| Maximum Load Current | 65 A |
| Inrush power in VA | 140-140 VA cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 13-13 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Motor power kW | 37 kW at 660...690 V AC 50 Hz (AC-3) |
| Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Insulation resistance | > 10 MOhm for control circuit |
| Quantity per set | set of 10 |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Range | TeSys |
| Flame retardance | V1 conforming to UL 94 |
| Overvoltage category | III |
| Item Name | Contactor |
| Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 |
| Protective cover | with |
| Tightening torque | control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver pozidriv No 2 |
| Average impedance | 1.5 Ohm - Ith 80 A 50 Hz for power circuit |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ie] rated operational current | 80 A (at <60 °C) at 240 V AC AC-1 for power circuit |
| Connections - terminals | power circuit: screw terminals 1 2.5-25mm² - cable stiffness: flexible without cable end |
| Control circuit type | AC at 50/60 Hz |
| Associated fuse rating | 125 A gG at <= 690 V coordination type 1 for power circuit |
| Depth | 118mm |
| Mounting support | rail |
| Pole contact composition | 3 NO |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Coil Power Rating | 37 kW |
| Mechanical durability | 6000000 cycles |
| Climatic withstand | conforming to IACS E10 exposure to damp heat |
| Coil technology | without built-in |
| Minimum switching voltage | 17 V for control circuit |
| Height | 122mm |
| Poles description | 3P |
| Width | 70mm |
| Operating altitude | 0...3000 m |
| Operating time | 4...19 ms opening |
| Device short name | LC1D |
| [Uc] control circuit voltage | 240 V AC 50/60 Hz |
| Compatibility code | LC1D |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 |
| Mechanical robustness | shocks contactor opened (10 Gn for 11 ms) |
| [Ue] rated operational voltage | power circuit: <= 690 V AC 25...400 Hz |
| [Ui] rated insulation voltage | control circuit: 600 V CSA certified |
| Standards | CSA C22.2 No 14 |
| Control circuit voltage limits | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz |
| Product certifications | CCC |
| Brand Name | Schneider Electric |
| Heat dissipation | 4-5 W at 50/60 Hz for control circuit |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Power dissipation per pole | 6.3 W AC-3 |
| Contact Configuration | 1 NO + 1 NC |
| Motor power hp | 20 hp at 230/240 V AC 60 Hz for 3 phases motors |
| Rated breaking capacity | 1000 kA at 440 V for power circuit conforming to IEC 60947 |
| Utilisation category | AC-3 |
| Coil Voltage | 240 VAC at 50 Hz |
| Net weight | 2.185 kg |
| Number of Poles | 3 |
| Product or component type | contactor |