Description
Schneider LC1K0910U7 Contactor, TeSys K, 3P, AC-3/AC-3e,<=440V 9A, aux. 1NO, 230...240V AC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 230-240V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Features:
• Free of Substances of Very High Concern above the threshold
• TeSys K is a compact contactor range with a wide variety of coil voltage and terminal connection options
• The offer features specific versions for railway (TeSys S207) and electrodomestic (TeSys S335) applications.
• One of the smallest contactor offerings in the market.
• The range delivers strong performance for its compact size and promises seamless integration in all applications.
• Widely used for industry, infrastructure and building applications.
• Designed for simple control systems
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Contactor application | motor control |
| Maximum operating rate | 3600 cyc/h |
| Minimum switching current | 5 mA for signalling circuit |
| Non overlap distance | 0.5mm |
| Irms rated making capacity | 110 A AC for signalling circuit conforming to IEC 60947 |
| Signalling circuit frequency | <= 400 Hz |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit |
| Supplier Code | LC1K0910U7 |
| GrosWeight | 177.000 g |
| [Icw] rated short-time withstand current | 85 A 50 °C - 5 s for power circuit |
| Maximum Load Current | 9 A |
| Warranty | 18 months |
| Inrush power in VA | 30-30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5-4.5 VA (at 20 °C) |
| Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-4 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Range | TeSys |
| Flame retardance | requirement 2 conforming to NF F 16-102 |
| Overvoltage category | III |
| Electrical durability | 0.16 Mcycles 20 A AC-1 at Ue <= 690 V |
| Item Name | Contactor |
| Volume | 193.440 cm3 |
| Protective treatment | TC conforming to DIN 50016 |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Auxiliary contact composition | 1 NO |
| [Ie] rated operational current | 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
| Connections - terminals | screw clamp terminals 1 cable(s) 0.75-4mm²flexible without cable end |
| Control circuit type | AC at 50/60 Hz |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947 |
| Depth | 57mm |
| Pole contact composition | 3 NO |
| Coil Power Rating | 4 kW |
| Mechanical durability | 10 Mcycles |
| Height | 58mm |
| Minimum switching voltage | 17 V for signalling circuit |
| Poles description | 3P |
| Width | 45mm |
| Operating altitude | 2000 m without derating |
| Operating time | 10...20 ms coil energisation and NO closing |
| [Uc] control circuit voltage | 230...240 V AC 50/60 Hz |
| Compatibility code | LC1K |
| Auxiliary contacts type | type instantaneous 1 NO |
| Mechanical robustness | shocks contactor opened- on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 |
| Device application | control |
| [Ue] rated operational voltage | signalling circuit: <= 690 V AC <= 400 Hz |
| Standards | UL 60335-2-40:Annex JJ |
| Control circuit voltage limits | drop-out: >= 0.20 Uc (at <50 °C) |
| Product certifications | CE |
| Brand Name | Schneider Electric |
| Heat dissipation | 1.3-1.3 W |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Contact Configuration | 1 NO |
| Length | 4.800 cm |
| Rated breaking capacity | 110 A at 380...400 V conforming to IEC 60947 |
| Utilisation category | AC-1 |
| Coil Voltage | 240 VAC |
| Number of Poles | 3 |
| Product or component type | contactor |
We would love your opinion