Schneider Electric GV2ME21 Motor circuit breaker, TeSys GV2, TeSys Deca, 3P, 17 to 23A, thermal magnetic, screw clamp terminals, button control, Dark Grey
Code: SCHGV2ME21
Unit of measure:
EACH
Description
TeSys GV motor circuit breaker, 3 poles (3P), 23A/690V, for 3-phase motor applications 9kW@400V. It provides a thermal-magnetic protection with a thermal setting range 17-23A, magnetic tripping at 13xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
•
•
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Power Rating | 18.5 kW |
Maximum operating rate | 25 cyc/h |
Ambient air temperature for operation | -20-60 °C |
Current Type | AC |
Supplier ref | GV2ME21 |
[Ith] conventional free air thermal current | 23 A conforming to IEC 60947-4-1 |
Supplier Code | GV2ME21 |
Connection Type | Screw Clamp |
Ambient air temperature for storage | -40-80 °C |
GrosWeight | 287.000 g |
Network frequency | 50/60 Hz conforming to IEC 60947-4-1 |
Warranty | 18 months |
Network type | AC |
Break Strength | 3 kA |
Fixing mode | panel: screwed (with adaptor plate) |
Motor power kW | 11-11 kW at 500 V AC 50/60 Hz |
Magnetic tripping current | 341-341 A |
Control type | push-button |
IP degree of protection | IP20 conforming to IEC 60529 |
Range | TeSys Deca |
Frequency Rating | 50/60 Hz |
Electrical durability | 100000 cycles for AC-3e at 415 V In |
Item Name | Motor Protection Circuit Breaker |
Volume | 379.440 cm3 |
Mounting position | horizontal |
Tightening torque | 1.7 N.m - on screw clamp terminal |
Thermal protection adjustment range | 17-23 A conforming to IEC 60947-4-1 |
Current | 17 - 23A |
[Ics] rated service short-circuit breaking capacity | 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
Standard | CCC, CSA, UL Listed |
Suitability for isolation | yes conforming to IEC 60947-1 |
[In] rated current | 23 A |
Depth | 78.5mm |
Colour | Dark Grey |
Fire resistance | 960 °C conforming to IEC 60695-2-11 |
Mechanical durability | 100000 cycles |
Climatic withstand | conforming to IACS E10 |
Voltage | 690 VAC |
Direct connector | without |
Breaking capacity | 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
Height | 89mm |
Poles description | 3P |
Width | 45mm |
Operating altitude | 2000 m |
Device short name | GV2ME |
Phase failure sensitivity | yes conforming to IEC 60947-4-1 |
Compatibility code | GV2ME |
Trip unit technology | thermal-magnetic |
Mechanical robustness | vibrations: 5 Gn- 5...150 Hz |
Device application | motor protection |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Standards | EN/IEC 60947-4-1 |
Product certifications | EAC |
Brand Name | Schneider Electric |
EAN/UPC | 3389110343212 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
Type | Thermal Magnetic |
Power dissipation per pole | 2.5 W |
Length | 8.500 cm |
Product name | TeSys GV2 |
Utilisation category | AC-3e conforming to IEC 60947-4-1 |
Rated duty | continuous conforming to IEC 60947-4-1 |
Net weight | 0.26 kg |
Number of Poles | 3 |
IK degree of protection | IK04 |
Product or component type | motor circuit breaker |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.