Schneider Electric GV2P10 Motor circuit breaker, TeSys GV2, TeSys Deca, 3P, 4 to 6.3A, thermal magnetic, screw clamp terminals, rotary handle, Dark Grey
Code: SCHGV2P10
Unit of measure:
EACH
Description
Motor Protection Circuit Breaker
Brand Name: Schneider
Type: Thermal Magnetic
Range: TeSys GV2
Voltage: 690 VAC
Current Type: AC
Current: 4 - 6.3 A
Power Rating: 4 kW
Number of Poles: 3
Break Strength: 6 kA
Frequency Rating: 50/60 Hz
Connection Type: Screw Clamp
Rotary Handle
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Maximum operating rate | 25 cyc/h |
Ambient air temperature for operation | -20-60 °C |
[Ith] conventional free air thermal current | 6.3 A conforming to IEC 60947-4-1 |
Supplier Code | GV2P10 |
Connection Type | Screw Terminal |
Ambient air temperature for storage | -40-80 °C |
Network frequency | 50/60 Hz conforming to IEC 60947-4-1 |
Network type | AC |
Fixing mode | panel: screwed (with 2 x M4 screws) |
Motor power kW | 3-3 kW at 500 V AC 50/60 Hz |
Magnetic tripping current | 91-91 A |
Control type | rotary handle |
IP degree of protection | IP20 conforming to IEC 60529 |
Range | Galaxy VL |
Electrical durability | 100000 cycles for AC-3e at 415 V In |
Item Name | Circuit Breaker |
Mounting position | vertical |
Tightening torque | 1.7 N.m - on screw clamp terminal |
Thermal protection adjustment range | 4-6.3 A conforming to IEC 60947-4-1 |
Current | 6.3A |
[Ics] rated service short-circuit breaking capacity | 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
Standard | CCC, CSA, UL Listed |
Suitability for isolation | yes conforming to IEC 60947-1 |
[In] rated current | 6.3 A |
Depth | 97mm |
Colour | Dark Grey |
Fire resistance | 960 °C conforming to IEC 60695-2-11 |
Mechanical durability | 100000 cycles |
Climatic withstand | conforming to IACS E10 |
Voltage | 690V |
Direct connector | without |
Breaking capacity | 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
Height | 89mm |
Poles description | 3P |
Width | 45mm |
Operating altitude | 2000 m |
Device short name | GV2P |
Phase failure sensitivity | yes conforming to IEC 60947-4-1 |
Compatibility code | GV2P |
Trip unit technology | thermal-magnetic |
Mechanical robustness | vibrations: 5 Gn- 5...150 Hz |
Device application | motor protection |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Standards | IEC/EN 60335-1:Clause 30.2 |
Product certifications | BV |
Brand Name | Schneider Electric |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
Power dissipation per pole | 2.5 W |
Product name | TeSys GV2 |
Utilisation category | AC-3 conforming to IEC 60947-4-1 |
Rated duty | continuous conforming to IEC 60947-4-1 |
IK degree of protection | IK04 |
Product or component type | motor circuit breaker |