Description
Schneider Electric A9D67425, Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 4P, 25A, C curve, 6000A/6kA, A type, 30mA
This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 4P RCBO with 4 protected poles, rated current is 25A, and operating voltage is 380VAC to 415VAC. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 280VAC to 415VAC is 6000A according to EN/IEC 61009-2-1 and 6kA according to EN/IEC 60947-2. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product color is white (RAL9003). The dimensions are (W) 72mm x (H) 86mm x (D) 78mm. The weight is 423g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Relative humidity | 95-95 % at 55-55 °C |
Number of protected poles | 4 |
Surge current | 250 A |
Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 |
Residual current tripping technology | voltage independent |
Ambient air temperature for operation | -25-60 °C |
[Ics] rated service breaking capacity | 6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
Earth-leakage protection | integrated |
Mounting mode | clip-on |
Comb busbar and distribution block compatibility | bottom: biconnect |
Earth-leakage sensitivity | 30 mA |
Ambient air temperature for storage | -40-70 °C |
Network frequency | 50 Hz |
9 mm pitches | 8 |
Network type | AC |
IP degree of protection | IP20 conforming to IEC 60529 |
Range | Acti9 |
Overvoltage category | III conforming to IEC 60364 |
Curve code | C |
Electrical durability | 10000 cycles |
Local signalling | ON, OFF, fault trip |
Tightening torque | 2-2 N.m |
Earth-leakage protection class | type A |
Connections - terminals | tunnel type terminal top or bottom 1-25 mm² flexible |
Contact position indicator | no |
Suitability for isolation | no conforming to IEC 60947-1 |
[In] rated current | 25 A |
Earth-leakage protection time delay | instantaneous |
Depth | 78 mm |
Connection pitch | 9 mm between poles |
Colour | white |
Mounting support | DIN rail |
Power losses per pole | 7.6 W |
Rated breaking and making capacity | Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
Range of product | Acti9 |
control type | toggle |
Mechanical durability | 20000 cycles |
Breaking capacity | 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2 |
Height | 86 mm |
Limitation class | 1 conforming to EN/IEC 61009-2-1 |
Poles description | 4P |
Width | 72 mm |
Quality labels | IMQ |
Wire stripping length | 12 mm for top or bottom connection |
Tropicalisation | 2 |
Device short name | iC60 RCBO |
Trip unit technology | thermal-magnetic |
Device application | distribution |
Device location in system | outgoer |
[Ue] rated operational voltage | 380...415 V AC 50 Hz |
Total power losses | 22.8 W |
[Ui] rated insulation voltage | 500 V AC 50 Hz |
Standards | EN/IEC 61009-2-1 |
Brand Name | Schneider Electric |
[Uimp] rated impulse withstand voltage | 4 kV |
Product name | Acti9 iC60 RCBO |
Magnetic tripping limit | 5...10 x In |
Net weight | 423 g |
Product or component type | residual current breaker with overcurrent protection (RCBO) |
Downloads
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
We can source just about anything, submit a request and we'll get back to you soon.