On Monday 17 February 2024, 8:00 PM (AEST) all pricing data will be unavailable while our systems perform an update, apologies for any inconvenience. Expected duration: 3 hours.
Schneider Electric XPSUAF13AP safety module, Harmony XPSU, Cat 4, potential free 2 NC, NO NC, 2 PNP, 24V AC or DC, screw
Code: SCHXPSUAF13AP
Unit of measure:
EACH
Width | 22.5mm |
Height | 100mm |
Depth | 120mm |
Depth | 120mm |
Height | 100mm |
Net weight | 0.200 kg |
Range | Harmony Safety Automation |
Width | 22.5mm |
Ambient air temperature for storage | -25-85 °C |
Associated fuse rating | 10 A gG for NO relay output circuit conforming to IEC 60947-1 |
Auxiliary contact composition | 3 NO |
Connections - terminals | removable screw terminal block- 2 x 0.25...1mm² flexible with ferrule without cable end- with bezel |
Electrical circuit type | PNP pair |
Function of module | light curtain monitoring |
IP degree of protection | IP54 (mounting area) conforming to IEC 60529 |
Input compatibility | antivalent pair conforming to ISO 14119 |
Input protection type | internal- electronic |
Input/output type | semiconductor pulsed diagnostic output 24 V DC- 20 mA Z1- not safety-related |
Local signalling | LED (red) for error |
Maximum line resistance | 500 Ohm |
Maximum response time on input open | 20 ms |
Minimum output current | 10 mA for relay output |
Minimum output voltage | 15 V for relay output |
Mounting support | 35mm symmetrical DIN rail |
Number of inputs | 2 safety input 24 V DC 5 |
Number of outputs | 3 on/off configurable pulsed output |
Power consumption in VA | 5.0 VA 24 V AC 50/60 Hz |
Power consumption in W | 2.0 W 24 V DC |
Product certifications | cULus |
Product or component type | safety module |
Relative humidity | 5-95 % non-condensing |
Safety level | can reach SIL 3 conforming to IEC 61508 |
Safety module application | for emergency stop- guard and light curtain monitoring |
Safety module name | XPSUAF |
Safety reliability data | HFT = 1 conforming to IEC 62061 |
Standards | ISO 13849-1 functional safety standard |
Supplier Code | XPSUAF13AP |
Synchronisation time between inputs | 2 s |
Type of start | automatic/manual/monitored |
[Ie] rated operational current | 3 A AC-15 for normally open relay contact |
[Ith] conventional free air thermal current | 8 A |
[Ui] rated insulation voltage | 250 V (pollution degree 2) conforming to IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
[Us] rated supply voltage | 24 V DC - 20...20 % |
SAFETY MODULE UAF CAT.4 24V SCREW