Description
Schneider Electric ATS430D88S6, Soft starter, Altivar Soft Starter ATS430, 88A, 208 to 600V AC, control supply 110 to 230V AC
This soft starter belongs to the Altivar Soft Starter ATS430 range which is intended to smoothly start and stop asynchronous motors supplied from 208 to 600V. With an operational rated current of 88A, it supplies motor from 22 to 55kW according to mains voltage. With an efficiency rating of 99.5%, torque control, high stress resistance, and complete monitoring, the ATS430 provides the essentials for effectiveness. Altivar Soft Starter ATS430 delivers best in class motor control with its torque control, the original by Schneider Electric. ATS430 provides complete system monitoring, including the motor, application, power and energy with an accuracy greater than 95%. The cybersecurity standards for ATS430 are met by incorporating best practices that help minimize downtime. Dimensions are 160mm (width), 230mm (depth), 289mm (height) and it weighs 6.6kg. ATS430 uses plastic with more than 20% bio-based content, and aluminum is ASI-certified. Altivar Soft Starter ATS430 is designed for applications such as pumps, fans, compressors, conveyors, and mixers. It conforms to IEC/EN 60947-4-2 and has received CE, cULus, UKCA, RCM, and CCC certifications. Some accessories are available, including an IP65 or IP43 remote mounting kit for installing a plain text or graphic display terminal on the enclosure door. The packaging is made from recycled cardboard and incorporates less single-use plastic. The ATS430 soft starters shall be mounted vertically inside an enclosure. The Altivar Soft Starter ATS430 range offers torque control, reliable operation, and simplicity. It also integrates essential features for the future, including cybersecurity best practices and condition monitoring. ATS430 delivers the essentials for effectiveness while lowering the overall equipment costs.
Features:
• Reduce time (design to operation) and overall cost
• Improved sustainability (enviromental performance, durability and efficiency)
• Reduced operational expenditure (high durability)
• Meets cybersecurity standards (integrates best practice features)
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Product destination | asynchronous motors |
With safety function Safe brake management (SBC/SBT) | false |
Relative humidity | 5-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
Data format | 8 bits, configurable odd, even or no parity for Modbus serial open style (DO, D1, PE, COM) |
With safety function Safe Speed Monitor (SSM) | false |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
Ambient air temperature for operation | 40-60 °C (with current derating of 1 % per °C above 40 °C) |
Connector type | open style |
Minimum switching current | 100 mA at 12 V DC for relay outputs |
Analogue output type | voltage output AQ1 : 0...10 V , impedance> 470 Ohm |
Ambient air temperature for storage | -40-70 °C |
Number of addresses | 0-247 for Modbus serial |
Apparent power | 70 VA |
Discrete input number | 4 |
Protection type | thermal protection: mains |
material declaration | true |
Motor power kW | 55 kW at 500 V in line normal duty |
Device connection | in line |
With safety function Safely Limited Position (SLP) | false |
Pollution degree | level 3 |
With sft fct Safe Stop 2 (SS2) | false |
With safety function Safely Limited Speed (SLS) | false |
Input compatibility | DI3: digital input level 1 PLC conforming to EN/IEC 61131-2 |
Product specific application | standard industrial machines |
Accuracy class | class 10E |
Discrete input logic | digital input DI3 at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
With safety function Safe torque off (STO) | false |
Depth | 230.2 mm |
Volume of cooling air | 31 m3/h |
internal bypass | true |
Output current drift | 150-700 % |
Maximum deflection under vibratory load (during transport) | 1.75 mm at 2...9 Hz |
Width | 160 mm |
Ambient air transport temperature | -40-70 °C |
Operating altitude | > 2000...4800 m with current derating 1 % per 100 m above 2000 m |
Display type | 1 LED (yellow) for COM2 |
Device short name | ATS430 |
NEMA degree of protection | open type |
Power loss static current independent | 19 W |
Maximum acceleration under vibratory load (during storage) | 1.5 gn at 200…500 Hz |
Method of access | slave Modbus serial |
[Ue] rated operational voltage | 575 V 75 hp normal duty |
Analogue output number | 1 |
Relay output number | 2 |
[Ui] rated insulation voltage | 600 V |
Transmission frame | RTU : open style (DO, D1, PE, COM) |
On-load factor | 50 % |
Environmental class (during operation) | class 3S3 according to IEC 60721-3-3 |
Supply frequency | 50...60 Hz - 20...20 % |
Analogue input number | 1 |
Torque control | true |
Discrete input type | (DI4) digital input, 4.4 kOhm |
Transmission rate | 0.3...115.2 kbps for Modbus serial open style (DO, D1, PE, COM) |
Net weight | 6.60 kg |
With safety function Safe Stop 1 (SS1) | false |
Operating position | vertical +/- 10 degree |
Electromagnetic compatibility | immunity to electrical transients level 4 conforming to IEC 61000-4-4 |
With safety function Safe Direction (SDI) | false |
Network frequency | 50...60 Hz |
Type of polarization | no impedance for Modbus serial |
With safety function Safe Operating Stop (SOS) | false |
Network number of phases | 3 phases |
With safety function Safe Position (SP) | false |
Function available | ports and services hardening |
Analogue input type | PTC2 : PTC temperature probe |
Maximum acceleration under shock load (during transport) | 10 gn at 11 ms |
Communication port protocol | Modbus serial open style (DO, D1, PE, COM) |
IP degree of protection | IP20 |
Voltage ramp | true |
Display screen available | true |
[Ie] rated operational current | normal duty: 88 A in line (at <40 °C) |
Maximum acceleration under vibratory load (during transport) | 1.5 gn at 200…500 Hz |
Overload current | 400 % Ie for 13 s |
Service factor | 100 |
Range of product | Altivar Soft Starter ATS430 |
Power loss per device current dependent | 11 W |
Power losses | 717 W during starting at 40 °C at 400% In |
Suitable for mounting onto standard rails | false |
Maximum switching current | relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1 |
Integrated motor overload protection | true |
Height | 289 mm |
Relay output type | relay outputs R2A, R2C NO |
Maximum acceleration under vibrational stress (during operation) | 1 gn at 13…200 Hz |
[Uc] control circuit voltage | 110...230 V AC 50...60 Hz - 15...10 % |
Rated current pwr loss specification | 88 A |
Discrete output number | 0 |
Marking | CE |
Maximum deflection under vibratory load (during storage) | 1.75 mm at 2...9 Hz |
Standards | UL 60947-4-2 |
With safety function Safe programmable logic | false |
Product certifications | UKCA |
Brand Name | Schneider Electric |
Maximum acceleration under shock impact (during operation) | 15 gn at 11 ms |
[Uimp] rated impulse withstand voltage | 6 kV |
Operating rate | 10 cyc/h |
Motor power hp | 60 hp at 460 V normal duty |
Utilisation category | AC-53A |
Physical interface | 2-wire RS 485 - connector(s): open style (DO, D1, PE, COM) |
Maximum acceleration under shock load (during storage) | 10 gn at 11 ms |
Product or component type | soft starter |
Downloads
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!