Brand Name | Schneider Electric |
Depth | 245.0mm |
Height | 325.0mm |
Net weight | 3.0 kg |
Range | Altivar Machine ATV320 |
Width | 60mm |
1 phase low current possible | false |
4 quadrant operation possible | true |
Acceleration and deceleration ramps | U |
Accuracy | +/- 2 % AQ1 for a temperature of -10...60 °C analog output |
Ambient air temperature for operation | -10-50 °C without derating |
Ambient air temperature for storage | -25-70 °C |
Ambient air transport temperature | -25-70 °C |
Analogue input number | 3 |
Analogue input type | AI2 bipolar differential voltage: +/- 10 V DC- impedance: 30 kOhm- resolution 10 bits |
Analogue output number | 1 |
Analogue output type | software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm- resolution 10 bits |
Apparent power | 9.1 kVA at 500 V (heavy duty) |
Application in domestic and commercial area permitted | false |
Application in industrial area permitted | true |
Asynchronous motor control profile | flux vector control without sensor - Energy Saving |
Base load current at high overload | 9.5 A |
Brake chopper integrated | true |
Braking to standstill | by DC injection |
Capacity of DC link | 560 µF |
Communication port protocol | CANopen |
Computer port | true |
Design of frequency changer | U converter |
Discrete input logic | negative logic (sink) |
Discrete input number | 7 |
Discrete input type | DI1...DI6 logic inputs- 24 V DC (30 V) |
Discrete output number | 3 |
Discrete output type | open collector DQ- 0-1 kHz 30 V DC 100 mA |
EMC filter | Class C2 EMC filter integrated |
EMC limit value (complied) | true |
Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 |
Encoder protocol | RS 422 |
Environmental class (during operation) | class 3S2 according to IEC 60721-3-3 |
Environmental class (during storage) | class 1S2 according to EN 60721-3 |
Environmental class (during transport) | class 2S1 according to EN 60721-3 |
Format of the drive | book |
Housing material | plastic |
IP degree of protection | IP20 |
Line current | 10.5 A at 500 V (heavy duty) |
Linearity error | AQ1: +/- 0.3 % for analog output |
Marking | RCM |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
Maximum associated fuse rating | 25.0 A |
Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
Maximum deflection under vibratory load (during storage) | 3.5mm at 2...13 Hz |
Maximum deflection under vibratory load (during transport) | 3.5mm at 2...13 Hz |
Maximum input current | 13.7 A |
Maximum output frequency | 0.599 kHz |
Maximum output voltage | 500 V |
Maximum switching current | relay output R1A- R1B- R1C- R2A- R2C on inductive load- cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC |
Method of access | slave CANopen |
Minimum switching current | relay output R1A- R1B- R1C- R2A- R2C: 5 mA at 24 V DC |
Motor power kW | 4.0 kW for heavy duty |
Motor slip compensation | not available in voltage/frequency ratio (2 or 5 points) |
Mounting mode | cabinet mount |
NEMA degree of protection | not applicable |
Network frequency | 50...60 Hz |
Network number of phases | 3 phases |
Nominal output current | 9.5 A |
Nominal output power | 4.0 kW |
Nominal switching frequency | 4 kHz |
Number of HW interfaces PROFINET | 0.0 |
Number of HW interfaces USB | 0.0 |
Number of HW interfaces industrial Ethernet | 0.0 |
Number of HW interfaces other | 1.0 |
Number of HW interfaces parallel | 0.0 |
Number of HW interfaces serial RS232 | 0.0 |
Number of HW interfaces serial RS422 | 0.0 |
Number of HW interfaces serial RS485 | 1.0 |
Number of HW interfaces serial TTY | 0.0 |
Number of input phases | 3 |
Number of inputs- bidirectional- not potential-free | 0 |
Number of inputs- potential-free | 0 |
Number of output phases | 3 |
Operating element present | true |
Operating position | vertical +/- 10 degree |
Optical interface present | false |
Option card | communication module- PROFINET |
Overvoltage category | III |
Permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
Permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
Permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
Pollution degree | 2 |
Power dissipation in W | fan: 111 W at 380 V- switching frequency 4 kHz |
Power loss per device current dependent | 111 W |
Power loss static current independent | 111 W |
Product certifications | KC |
Product or component type | variable speed drive |
Product specific application | complex machines |
Prospective line Isc | 5 kA |
Protection type | overcurrent between output phases and earth: drive |
Refresh time | relay output (R2A- R2C): 2 ms |
Regulation loop | adjustable PID regulator |
Relative symmetric mains voltage tolerance | 10 % |
Relative symmetric network frequency tolerance | 5 % |
Relay output type | configurable relay logic R2C |
Sampling duration | 2 ms (AQ1) - analog output |
Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
Standards | IEC 61800-5-1 |
Supplier Code | ATV320U40N4B |
Supporting protocol for AS-Interface Safety at Work | false |
Supporting protocol for ASI | false |
Supporting protocol for BACnet | false |
Supporting protocol for CAN | true |
Supporting protocol for Data-Highway | false |
Supporting protocol for DeviceNet | true |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for EtherNet/IP | true |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for INTERBUS | false |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for KNX | false |
Supporting protocol for LON | false |
Supporting protocol for MODBUS | true |
Supporting protocol for PROFIBUS | true |
Supporting protocol for PROFINET CBA | false |
Supporting protocol for PROFINET IO | true |
Supporting protocol for PROFIsafe | false |
Supporting protocol for SERCOS | false |
Supporting protocol for SUCONET | false |
Supporting protocol for SafetyBUS P | false |
Supporting protocol for TCP/IP | true |
Supporting protocol for other bus systems | true |
Switching frequency | 4...16 kHz with derating factor |
Synchronous motor control profile | vector control without sensor |
Transient overtorque | 170-200 % of nominal motor torque |
Variant | standard version |
Volume of cooling air | 11.3 m3/h |
With safety function Safe Direction (SDI) | false |
With safety function Safe Operating Stop (SOS) | false |
With safety function Safe Position (SP) | false |
With safety function Safe Speed Monitor (SSM) | false |
With safety function Safe Stop 1 (SS1) | true |
With safety function Safe brake management (SBC/SBT) | false |
With safety function Safe programmable logic | false |
With safety function Safe torque off (STO) | true |
With safety function Safely Limited Position (SLP) | false |
With safety function Safely Limited Speed (SLS) | true |
With sft fct Safe Stop 2 (SS2) | false |
[Us] rated supply voltage | 380...500 V - 15...10 % |