Schneider Electric LC1D50N7 Contactor, Tesys Deca, 3P(3NO),AC-3/AC-3e 440V 50A,coil 415V AC, screw clamp terminals
Code: SCHLC1D50N7
Unit of measure:
EACH
Description
Contactor
Brand Name: Schneider
Coil Voltage: 415 VAC
Contact Configuration: 1 NO + 1 NC
Number of Poles: 3
Maximum Load Current: 50 A
Coil Power Rating: 25 kW
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Contactor application | motor control |
Maximum operating rate | 3600 cyc/h 60 °C |
Non-overlap time | 1.5 ms on energisation between NC and NO contacts |
Minimum switching current | 5 mA for control circuit |
Irms rated making capacity | 140 A AC for control circuit conforming to IEC 60947-5-1 |
[Ith] conventional free air thermal current | 80 A (at 60 °C) for power circuit |
Supplier Code | LC1D50N7 |
Maximum Load Current | 50 A |
Inrush power in VA | 160-160 VA cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 15-15 VA 50 Hz cos phi 0.3 (at 20 °C) |
Motor power kW | 15 kW at 220...230 V AC 50 Hz (AC-3e) |
Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Insulation resistance | > 10 MOhm for control circuit |
IP degree of protection | IP2X conforming to VDE 0106 |
Range | TeSys |
Flame retardance | V1 conforming to UL 94 |
Overvoltage category | III |
Item Name | Contactor |
Protective cover | with |
Tightening torque | control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver pozidriv No 2 |
Auxiliary contact composition | 1 NO + 1 NC |
[Ie] rated operational current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
Connections - terminals | control circuit: screw clamp terminals 1 1-4mm² - cable stiffness: flexible without cable end |
Control circuit type | AC at 50/60 Hz |
Associated fuse rating | 100 A gG at <= 690 V coordination type 2 for power circuit |
Depth | 119mm |
Mounting support | plate |
Pole contact composition | 3 NO |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Coil Power Rating | 25 kW |
Mechanical durability | 6000000 cycles |
Climatic withstand | conforming to IACS E10 exposure to damp heat |
Coil technology | without built-in bidirectional peak limiting diode suppressor |
Minimum switching voltage | 17 V for control circuit |
Height | 127mm |
Poles description | 3P |
Width | 75mm |
Operating altitude | 0...3000 m |
Operating time | 12...26 ms closing |
Device short name | LC1D |
[Uc] control circuit voltage | 415 V AC 50/60 Hz |
Compatibility code | LC1D |
Auxiliary contacts type | type mirror contact 1 NC conforming to IEC 60947-4-1 |
Mechanical robustness | vibrations contactor opened (2 Gn- 5...300 Hz) |
[Ue] rated operational voltage | power circuit: <= 690 V AC 25...400 Hz |
[Ui] rated insulation voltage | control circuit: 690 V conforming to IEC 60947-1 |
Terminals description ISO n°1 | (A1-A2)CO |
Standards | UL 508 |
Control circuit voltage limits | 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
Product certifications | UL |
Brand Name | Schneider Electric |
Heat dissipation | 4-5 W at 50/60 Hz for control circuit |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
Power dissipation per pole | 9.6 W AC-1 |
Contact Configuration | 1 NO + 1 NC |
Motor power hp | 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors |
Rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
Utilisation category | AC-2 |
Coil Voltage | 415 VAC |
Net weight | 1.4 kg |
Number of Poles | 3 |
Product or component type | contactor |