Description
Schneider Electric LC1DT200A6BNE, Contactor, Tesys Deca Advanced, 4P(4NO), AC-1, <=440V, 200A, 24-60V AC/DC coil,lugs-ring or bars
TeSys Deca Advanced contactor, 3 poles (3NO) for category AC-1 applications up to 200A@440V. It is equipped with a 24-60V AC/DC wide-band electronic coil that has lower power consumption, along with integrated 1NO+1NC auxiliary contacts. It can be installed in any orientation, and LRD43 could be directly mounted below contactor. The operating temperature range is between -40°C and 70°C, and it can be installed at altitudes of up to 3000m without derating. It is designed for demanding applications with improved performance under harsh environment including salt-mist, dust and high shock. The dimension is 152mm x 134mm x 155mm (H x W x D). Compact size enables panel space savings. Simple wiring with all front access to control circuit enhances accessibility and safety. Front IP20 as well as improved main power connection robustness is achieved by EverLink. Multi standards certified (CE,CB,CCC,cULus,KC,RCM). Unique QR code provides quick access to complete product data.
Features:
• Efficient solution combining robustness with ease of use, ensuring customers experience reliability without complexity
• Electronic wide-band coil withstands voltage fluctuations allows quick coil operating frequency and ensures long uptime
• Sustainability is advanced with 50% coil inrush savings.
• Fewer references covering wider applications means simpler to select and less inventory to carry
• Compact size with robust EverLink power connection improves operational efficiency and eliminates future maintenance
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Contactor application | resistive load |
Hold-in power consumption in W | 5.1-5.1 W at 20 °C |
Maximum operating rate | 2400 cyc/h at 60 °C, 3600 cyc/h at Uc at 20 ºC |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
Minimum switching current | 5 mA for signalling circuit |
Irms rated making capacity | 1260 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Signalling circuit frequency | 16.67...400 Hz |
[Ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
Inrush power in W | 136-136 W (at 20 °C) |
Inrush power in VA | 170-170 VA (at 20 °C) |
Hold-in power consumption in VA | 7.5-7.5 VA (at 20 °C) |
Safety reliability level | B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1, B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
Insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 front face conforming to IEC 60529 |
Range | TeSys Deca |
Overvoltage category | III |
Electrical durability | 0.38 Mcycles 200 A AC-1 at Ue <= 440 V |
Protective treatment | none conforming to IEC 60068-2-30 |
Protective cover | with |
Pollution degree | 3 |
Average impedance | 0.45 mOhm - Ith 200 A 50 Hz for power circuit |
Auxiliary contact composition | 1 NO + 1 NC |
[Ie] rated operational current | 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
Control circuit type | AC at 50/60 Hz, DC |
Associated fuse rating | 10 A gG for signalling circuit, 2 A gG for control circuit, 315 A gG at <= 690 V for power circuit |
Depth | 155 mm |
Fire resistance | 850 °C conforming to IEC 60695-2-11 |
Mounting support | plate |
Pole contact composition | 4 NO |
Range of product | TeSys Deca Advanced |
Climatic withstand | conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
Mechanical durability | 8 Mcycles |
Permissible ambient air temperature around the device | -40-60 °C operation, 60-70 °C with derating, -60-80 °C storage |
Coil technology | built-in bidirectional peak limiting diode suppressor |
Height | 152 mm |
Minimum switching voltage | 17 V for signalling circuit |
Poles description | 4P |
Width | 134 mm |
Operating altitude | 0...3000 m without derating |
Operating time | 10...80 ms opening, 20...90 ms closing |
[Uc] control circuit voltage | 24...60 V AC 50/60 Hz, 24...60 V DC |
Device short name | LC1D |
Compatibility code | LC1D |
Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1 |
[Ue] rated operational voltage | power circuit: <= 1000 V AC 16.67...400 Hz, power circuit: <= 300 V DC |
[Ui] rated insulation voltage | power circuit: 1000 V conforming to IEC 60947-4-1, power circuit: 600 V CSA certified, power circuit: 600 V UL certified, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified, signalling circuit: 690 V conforming to IEC 60947-1 |
Standards | CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, JIS C8201-4-1, JIS C8201-5-1, UL 60947-4-1, UL 60947-5-1 |
Control circuit voltage limits | 0.1 Uc Max (-40-60 °C):drop-out AC/DC, 0.8 Uc Min...1.1 Uc Max (-40-60 °C):operational AC/DC |
Product certifications | CB Scheme, CCC, CE, cULus, EU-RO-MR by DNV-GL, UKCA |
Brand Name | Schneider Electric |
Heat dissipation | 2.2-2.2 W at 20 °C |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
Power dissipation per pole | 28.1 W AC-1, 6 W AC-3, 6 W AC-3e |
Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
Utilisation category | AC-1, AC-3, AC-3e, AC-4, DC-1, DC-3, DC-5 |
Net weight | 2.6 kg |
Product or component type | contactor |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
We can source just about anything, submit a request and we'll get back to you soon.