Description
EasyPact TVS contactor 3 poles for motor applications up to 9A 4kW@440V. It provides a 240V 50Hz AC coil, 1NO built-in auxiliary contacts, power and control connections by screw clamp terminals. 45mm width for standard operating rates up to 1800 cycles per hour. It procures standard reliability and durability with 1.4 Mcycles electrical durability AC-3 and 10 Mcycles mechanical durability. It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).
• Designed to meet the requirements of Electro domestic and HVAC applications
• Easier to install and operate with multi-standard screws
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Contactor application | resistive load |
Maximum operating rate | 1800 cyc/h 60 °C |
Non-overlap time | 1.5 ms on de-energisation guaranteed between NC and NO contact |
Minimum switching current | 5 mA for control circuit |
Irms rated making capacity | 90 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
[Ith] conventional free air thermal current | 25 A (at 55 °C) for power circuit |
Supplier Code | LC1E0910U5 |
GrosWeight | 339.000 g |
[Icw] rated short-time withstand current | 30 A 40 °C - 600 s for power circuit |
Warranty | 18 months |
Inrush power in VA | 95-95 VA 60 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 8.5-8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
Motor power kW | 5.5 kW at 500 V AC 50/60 Hz |
Insulation resistance | > 10 MOhm for control circuit |
IP degree of protection | IP2X conforming to IEC 60529 |
Range | Easy TeSys |
Overvoltage category | III |
Electrical durability | 150000 cycles AC-1 |
Volume | 318.750 cm3 |
Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 |
Pollution degree | 3 |
Tightening torque | control circuit: 1.2 N.m |
Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
Auxiliary contact composition | 1 NO |
[Ie] rated operational current | 9 A (at <55 °C) at <= 440 V AC AC-3e for power circuit |
Connections - terminals | control circuit: screw clamp terminals 2 1-4mm² - cable stiffness: solid without cable end |
Control circuit type | AC at 50 Hz |
Associated fuse rating | 20 A gG at <= 690 V coordination type 1 for power circuit |
Depth | 80mm |
Mounting support | plate |
Pole contact composition | 3 NO |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Mechanical durability | 10000000 cycles |
Permissible ambient air temperature around the device | -5-55 °C operation |
Height | 74mm |
Minimum switching voltage | 17 V for control circuit |
Poles description | 3P |
Width | 45mm |
Operating altitude | 3000 m without derating |
Operating time | 4...19 ms on opening |
Device short name | LC1E |
[Uc] control circuit voltage | 240 V AC 50 Hz |
Mechanical robustness | vibrations contactor closed (3 Gn- 5...300 Hz) |
[Ue] rated operational voltage | power circuit: <= 690 V AC 50/60 Hz |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
Standards | IEC 60947-4-1 |
Control circuit voltage limits | 0.3...0.6 Uc (-5-55 °C):drop-out 50 Hz |
Product certifications | EAC |
Brand Name | Schneider Electric |
Heat dissipation | 2-3 W for control circuit |
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
Power dissipation per pole | 1.6 W AC-1 |
Length | 7.500 cm |
Rated breaking capacity | 72 A at 440 V for power circuit conforming to IEC 60947 |
Utilisation category | AC-3e |
Net weight | 0.3 kg |
Product or component type | contactor |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
We can source just about anything, submit a request and we'll get back to you soon.