Schneider Electric LC2K0910B7 reversing Contactor, TeSys K, 3P, AC-3/AC-3e,440V 9A, 1NO, 24V AC coil
Code: SCHLC2K0910B7
Unit of measure:
EACH
Description
REVERSING CONTACTOR 4KW 2NO-AUX 24VAC
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Contactor application | resistive load |
Maximum operating rate | 3600 cyc/h |
Ambient air temperature for operation | -25-50 °C |
Minimum switching current | 5 mA for signalling circuit |
Non overlap distance | 0.5mm |
Irms rated making capacity | 110 A AC for signalling circuit conforming to IEC 60947 |
Signalling circuit frequency | <= 400 Hz |
[Ith] conventional free air thermal current | 10 A (at 50 °C) for signalling circuit |
Supplier Code | LC2K0910B7 |
Ambient air temperature for storage | -50-80 °C |
Interlocking type | mechanical |
[Icw] rated short-time withstand current | 40 A 50 °C - 3 min for power circuit |
Inrush power in VA | 30-30 VA (at 20 °C) |
Hold-in power consumption in VA | 4.5-4.5 VA (at 20 °C) |
Motor power kW | 4 kW at 380...415 V AC 50/60 Hz |
Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 conforming to VDE 0106 |
Range | TeSys |
Flame retardance | requirement 2 conforming to NF F 16-102 |
Overvoltage category | III |
Electrical durability | 1.3 Mcycles 9 A AC-3e at Ue <= 440 V |
Device presentation | preassembled with reversing power busbar |
Protective treatment | TC conforming to DIN 50016 |
Tightening torque | 0.8-1.3 N.m - on screw clamp terminals pozidriv No 2 |
Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Auxiliary contact composition | 1 NO |
[Ie] rated operational current | 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
Connections - terminals | screw clamp terminals 2 cable(s) 1.5-4mm²solid |
Control circuit type | AC at 50/60 Hz |
Associated fuse rating | 10 A gG for signalling circuit conforming to VDE 0660 |
Depth | 57mm |
Mounting support | plate |
Pole contact composition | 3 NO |
Mechanical durability | 5 Mcycles |
Minimum switching voltage | 17 V for signalling circuit |
Height | 58mm |
Poles description | 3P |
Width | 90mm |
Operating altitude | 2000 m without derating |
Operating time | 10...20 ms coil de-energisation and NO opening |
Device short name | LC2K |
[Uc] control circuit voltage | 24 V AC 50/60 Hz |
Compatibility code | LC2K |
Auxiliary contacts type | type instantaneous 1 NO |
Mechanical robustness | shocks contactor opened- on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 |
Device application | control |
[Ue] rated operational voltage | signalling circuit: <= 690 V AC 50/60 Hz |
[Ui] rated insulation voltage | signalling circuit: 690 V conforming to IEC 60947-5-1 |
Standards | JIS C8201-4-1 |
Control circuit voltage limits | drop-out: 0.2...0.75 Uc (at <50 °C) |
Product certifications | CSA |
Brand Name | Schneider Electric |
Heat dissipation | 1.3-1.3 W |
[Uimp] rated impulse withstand voltage | 8 kV |
Product name | TeSys K |
Rated breaking capacity | 110 A at 380...400 V conforming to IEC 60947 |
Utilisation category | AC-3e |
Net weight | 0.39 kg |
Product or component type | reversing contactor |