Description
Schneider LRD02 TeSys, TeSys Deca, Thermal overload relay, 690VAC, 0.16 to 0.25A, 1NO+1NC, class 10A
TeSys LRD thermal overload relay, 0.4A/690V, thermal setting range 0.25-0.4A, tripping class 10A, for protection of 3-phase motors 0.09kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Mount | Plate, with specific accessories |
| Thermal overload class | class 10A conforming to IEC 60947-4-1 |
| Ambient air temperature for operation | -20-60 °C without derating conforming to IEC 60947-4-1 |
| Current Type | AC |
| Supplier ref | LRD03 |
| Contactor | LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38 |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Supplier Code | LRD03 |
| Ambient air temperature for storage | -60-70 °C |
| Trip Class | Class 10A |
| Permissible current | 0.22 A at 125 V DC-13 for signalling circuit |
| Network frequency | 0...400 Hz |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Network type | DC |
| Terminal Type | Screw Clamp |
| Control type | blue push-button: reset |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Range | TeSys Deca |
| Flame retardance | V1 conforming to UL 94 |
| Weight | 0.124 kg |
| Frequency Rating | 0 - 400 Hz |
| Item Name | Overload Relay |
| Tightening torque | power circuit: 1.7 N.m - on screw clamp terminals |
| Thermal protection adjustment range | 0.25-0.4 A |
| Auxiliary contact composition | 1 NO + 1 NC |
| Current | 0.25 - 0.4A |
| Connections - terminals | power circuit: screw clamp terminals 1 cable(s) 1.5-10mm² flexible without cable end |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A BS for signalling circuit |
| Standard | CSA, UL Listed |
| Depth | 70mm |
| Mounting support | under contactor |
| Climatic withstand | conforming to IACS E10 |
| Voltage | 690 V |
| Degree of Protection | IP20 |
| Height | 66mm |
| Width | 45mm |
| Temperature Rating | -20 to 60 deg C |
| Device short name | LRD |
| Phase failure sensitivity | tripping current 130 % of Ir on two phase- the last one at 0 |
| Compatibility code | LRD |
| Product compatibility | LC1D12 |
| Mechanical robustness | shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| [Ui] rated insulation voltage | power circuit: 600 V conforming to UL |
| Temperature compensation | -20-60 °C |
| Standards | EN/IEC 60947-4-1 |
| Product certifications | UKCA |
| Brand Name | Schneider Electric |
| EAN/UPC | 3389110346732 |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Type | Thermal |
| Reset Type | Manual/Automatic |
| IP Rating | IP20 |
| Product name | TeSys Deca |
| Relay application | motor protection |
| Frequency | 0...400 Hz |
| Net weight | 0.124 kg |
| Product or component type | differential thermal overload relay |