Schneider Electric LU2B12BL Reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690VAC, 24VDC coil
Code: SCHLU2B12BL
Unit of measure:
EACH
Description
REVERSER 12A 24VDC
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Maximum operating rate | 3600 cyc/h |
Safe separation of circuit | 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N |
Ambient air temperature for operation | -25-70 °C with LUCA- LUCB- LUCC- LUCD |
[Ics] rated service breaking capacity | 4 kA at 690 V |
[Ith] conventional free air thermal current | 12 A |
Supplier Code | LU2B12BL |
Ambient air temperature for storage | -40-85 °C |
Network frequency | 40...60 Hz |
Vibration resistance | 4 gn (f= 5-300 Hz) power poles closed conforming to IEC 60068-2-27 |
Resistance to radiated fields | 10 V/m 3 conforming to IEC 61000-4-3 |
Shock resistance | 15 gn power poles closed conforming to IEC 60068-2-27 |
Fixing mode | screw-fixed (plate) |
Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
IP degree of protection | IP20 conforming to IEC 60947-1 (other faces) |
Range | TeSys |
Immunity to voltage dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
Protective treatment | TH conforming to IEC 60068 |
Tightening torque | power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6mm |
Auxiliary contact composition | 1 NO + 1 NC |
[Ie] rated operational current | 12 A at 500 V |
Connections - terminals | power circuit: screw clamp terminals 1 cable(s) 2.5-10mm² flexible without cable end |
Typical current consumption | 120 mA at 24 V DC I rms sealed |
Resistance to fast transients | 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
Suitability for isolation | yes |
Depth | 126mm |
Fire resistance | 650 °C conforming to IEC 60695-2-12 |
Resistance to electrostatic discharge | 8 kV level 4 on contact conforming to IEC 61000-4-2 |
Mechanical durability | 15 Mcycles |
Height | 224mm |
Poles description | 3P |
Width | 45mm |
Operating altitude | 2000 m |
Operating time | 75 ms closing with LUCM for control circuit |
[Uc] control circuit voltage | 24 V DC |
Device short name | LU2B |
Compatibility code | LU2B |
Auxiliary contacts type | type mirror contact (1 NC) conforming to IEC 60947-1 |
Product compatibility | control unit LUC.12BL |
Device application | motor protection |
[Ue] rated operational voltage | 690 V AC for power circuit |
[Ui] rated insulation voltage | 600 V conforming to UL 60947-4-1 |
Standards | CSA C22.2 No 60947-4-1- with phase barrier |
Control circuit voltage limits | 20...27 V DC in operation |
Product certifications | ASEFA |
Brand Name | Schneider Electric |
Immunity to radioelectric fields | 10 V conforming to IEC 61000-4-6 |
Heat dissipation | 1.7-1.7 W for control circuit with LUCM |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-6-2 |
Inrush restraint duration | 15 ms DC |
Immunity to microbreaks | 3 ms for control circuit |
Product name | TeSys Ultra |
Utilisation category | AC-44 |
Net weight | 1.27 kg |
Product or component type | reversing power base |